ServiceConfig.DispatcherConfig.Builder

publiczna statyczna klasa końcowa ServiceConfig.DispatcherConfig.Builder

 Configuration for a tf.data service DispatchServer.
 
Typ protokołu tensorflow.data.experimental.DispatcherConfig

Metody publiczne

ServiceConfig.DispatcherConfig.Builder
addRepeatedField (pole com.google.protobuf.Descriptors.FieldDescriptor, wartość obiektu)
ServiceConfig.DispatcherConfig
ServiceConfig.DispatcherConfig
ServiceConfig.DispatcherConfig.Builder
jasne ()
ServiceConfig.DispatcherConfig.Builder
clearFaultTolerantMode ()
 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts.
ServiceConfig.DispatcherConfig.Builder
clearField (pole com.google.protobuf.Descriptors.FieldDescriptor)
ServiceConfig.DispatcherConfig.Builder
clearJobGcCheckIntervalMs ()
 How often the dispatcher should scan through to delete old and unused jobs.
ServiceConfig.DispatcherConfig.Builder
clearJobGcTimeoutMs ()
 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
ServiceConfig.DispatcherConfig.Builder
clearOneof (com.google.protobuf.Descriptors.OneofDescriptor oneof)
ServiceConfig.DispatcherConfig.Builder
wyczyśćPort ()
 The port for the dispatcher to bind to.
ServiceConfig.DispatcherConfig.Builder
wyczyśćProtokół ()
 The protocol for the dispatcher to use when connecting to workers.
ServiceConfig.DispatcherConfig.Builder
wyczyśćKatalog Pracy ()
 A work directory to use for storing dispatcher state, and for recovering
 during restarts.
ServiceConfig.DispatcherConfig.Builder
klon ()
ServiceConfig.DispatcherConfig
końcowy statyczny com.google.protobuf.Descriptors.Descriptor
com.google.protobuf.Descriptors.Descriptor
wartość logiczna
getFaultTolerantMode ()
 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts.
długi
getJobGcCheckIntervalMs ()
 How often the dispatcher should scan through to delete old and unused jobs.
długi
getJobGcTimeoutMs ()
 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
długi
pobierzPort ()
 The port for the dispatcher to bind to.
Strunowy
pobierz protokół ()
 The protocol for the dispatcher to use when connecting to workers.
com.google.protobuf.ByteString
getProtocolBytes ()
 The protocol for the dispatcher to use when connecting to workers.
Strunowy
getWorkDir ()
 A work directory to use for storing dispatcher state, and for recovering
 during restarts.
com.google.protobuf.ByteString
getWorkDirBytes ()
 A work directory to use for storing dispatcher state, and for recovering
 during restarts.
końcowa wartość logiczna
ServiceConfig.DispatcherConfig.Builder
mergeFrom (wejście com.google.protobuf.CodedInputStream, com.google.protobuf.ExtensionRegistryLite ExtensionRegistry)
ServiceConfig.DispatcherConfig.Builder
mergeFrom (com.google.protobuf.Wiadomość inna)
końcowy ServiceConfig.DispatcherConfig.Builder
mergeUnknownFields (com.google.protobuf.UnknownFieldUstaw nieznane pola)
ServiceConfig.DispatcherConfig.Builder
setFaultTolerantMode (wartość logiczna)
 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts.
ServiceConfig.DispatcherConfig.Builder
setField (pole com.google.protobuf.Descriptors.FieldDescriptor, wartość obiektu)
ServiceConfig.DispatcherConfig.Builder
setJobGcCheckIntervalMs (długa wartość)
 How often the dispatcher should scan through to delete old and unused jobs.
ServiceConfig.DispatcherConfig.Builder
setJobGcTimeoutMs (długa wartość)
 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
ServiceConfig.DispatcherConfig.Builder
setPort (długa wartość)
 The port for the dispatcher to bind to.
ServiceConfig.DispatcherConfig.Builder
setProtocol (wartość ciągu)
 The protocol for the dispatcher to use when connecting to workers.
ServiceConfig.DispatcherConfig.Builder
setProtocolBytes (wartość com.google.protobuf.ByteString)
 The protocol for the dispatcher to use when connecting to workers.
ServiceConfig.DispatcherConfig.Builder
setRepeatedField (pole com.google.protobuf.Descriptors.FieldDescriptor, indeks int, wartość obiektu)
końcowy ServiceConfig.DispatcherConfig.Builder
setUnknownFields (com.google.protobuf.UnknownFieldUstaw nieznane pola)
ServiceConfig.DispatcherConfig.Builder
setWorkDir (wartość ciągu)
 A work directory to use for storing dispatcher state, and for recovering
 during restarts.
ServiceConfig.DispatcherConfig.Builder
setWorkDirBytes (wartość com.google.protobuf.ByteString)
 A work directory to use for storing dispatcher state, and for recovering
 during restarts.

Metody dziedziczone

Metody publiczne

public ServiceConfig.DispatcherConfig.Builder addRepeatedField (pole com.google.protobuf.Descriptors.FieldDescriptor, wartość obiektu)

public ServiceConfig.DispatcherConfig kompilacja ()

public ServiceConfig.DispatcherConfig buildPartial ()

public ServiceConfig.DispatcherConfig.Builder clearFaultTolerantMode ()

 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts. Requires that `work_dir` is nonempty.
 
bool fault_tolerant_mode = 4;

public ServiceConfig.DispatcherConfig.Builder clearField (pole com.google.protobuf.Descriptors.FieldDescriptor)

public ServiceConfig.DispatcherConfig.Builder clearJobGcCheckIntervalMs ()

 How often the dispatcher should scan through to delete old and unused jobs.
 
int64 job_gc_check_interval_ms = 5;

public ServiceConfig.DispatcherConfig.Builder clearJobGcTimeoutMs ()

 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
 
int64 job_gc_timeout_ms = 6;

public ServiceConfig.DispatcherConfig.Builder clearOneof (com.google.protobuf.Descriptors.OneofDescriptor oneof)

public ServiceConfig.DispatcherConfig.Builder clearPort ()

 The port for the dispatcher to bind to. A value of 0 indicates that the
 dispatcher may bind to any available port.
 
int64 port = 1;

public ServiceConfig.DispatcherConfig.Builder clearProtocol ()

 The protocol for the dispatcher to use when connecting to workers.
 
string protocol = 2;

public ServiceConfig.DispatcherConfig.Builder clearWorkDir ()

 A work directory to use for storing dispatcher state, and for recovering
 during restarts. The empty string indicates not to use any work directory.
 
string work_dir = 3;

public ServiceConfig.DispatcherConfig getDefaultInstanceForType ()

public static final com.google.protobuf.Descriptors.Descriptor getDescriptor ()

public com.google.protobuf.Descriptors.Descriptor getDescriptorForType ()

publiczna wartość logiczna getFaultTolerantMode ()

 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts. Requires that `work_dir` is nonempty.
 
bool fault_tolerant_mode = 4;

publiczny długi getJobGcCheckIntervalMs ()

 How often the dispatcher should scan through to delete old and unused jobs.
 
int64 job_gc_check_interval_ms = 5;

publiczny długi getJobGcTimeoutMs ()

 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
 
int64 job_gc_timeout_ms = 6;

publiczny długi getPort ()

 The port for the dispatcher to bind to. A value of 0 indicates that the
 dispatcher may bind to any available port.
 
int64 port = 1;

publiczny ciąg getProtocol ()

 The protocol for the dispatcher to use when connecting to workers.
 
string protocol = 2;

public com.google.protobuf.ByteString getProtocolBytes ()

 The protocol for the dispatcher to use when connecting to workers.
 
string protocol = 2;

publiczny ciąg getWorkDir ()

 A work directory to use for storing dispatcher state, and for recovering
 during restarts. The empty string indicates not to use any work directory.
 
string work_dir = 3;

publiczny com.google.protobuf.ByteString getWorkDirBytes ()

 A work directory to use for storing dispatcher state, and for recovering
 during restarts. The empty string indicates not to use any work directory.
 
string work_dir = 3;

publiczna końcowa wartość logiczna isInitialized ()

public ServiceConfig.DispatcherConfig.Builder mergeFrom (wejście com.google.protobuf.CodedInputStream, com.google.protobuf.ExtensionRegistryLite ExtensionRegistry)

Rzuca
Wyjątek IO

public ServiceConfig.DispatcherConfig.Builder mergeFrom (com.google.protobuf.Message other)

publiczna wersja końcowa ServiceConfig.DispatcherConfig.Builder mergeUnknownFields (com.google.protobuf.UnknownFieldSetknownFields)

public ServiceConfig.DispatcherConfig.Builder setFaultTolerantMode (wartość logiczna)

 Whether to run in fault tolerant mode, where dispatcher state is saved
 across restarts. Requires that `work_dir` is nonempty.
 
bool fault_tolerant_mode = 4;

public ServiceConfig.DispatcherConfig.Builder setField (pole com.google.protobuf.Descriptors.FieldDescriptor, wartość obiektu)

public ServiceConfig.DispatcherConfig.Builder setJobGcCheckIntervalMs (długa wartość)

 How often the dispatcher should scan through to delete old and unused jobs.
 
int64 job_gc_check_interval_ms = 5;

public ServiceConfig.DispatcherConfig.Builder setJobGcTimeoutMs (długa wartość)

 How long a job needs to be unused before it becomes a candidate for garbage
 collection.
 
int64 job_gc_timeout_ms = 6;

public ServiceConfig.DispatcherConfig.Builder setPort (długa wartość)

 The port for the dispatcher to bind to. A value of 0 indicates that the
 dispatcher may bind to any available port.
 
int64 port = 1;

public ServiceConfig.DispatcherConfig.Builder setProtocol (wartość ciągu)

 The protocol for the dispatcher to use when connecting to workers.
 
string protocol = 2;

public ServiceConfig.DispatcherConfig.Builder setProtocolBytes (wartość com.google.protobuf.ByteString)

 The protocol for the dispatcher to use when connecting to workers.
 
string protocol = 2;

public ServiceConfig.DispatcherConfig.Builder setRepeatedField (pole com.google.protobuf.Descriptors.FieldDescriptor, indeks int, wartość obiektu)

publiczny końcowy ServiceConfig.DispatcherConfig.Builder setUnknownFields (com.google.protobuf.UnknownFieldSetknownFields)

public ServiceConfig.DispatcherConfig.Builder setWorkDir (wartość ciągu)

 A work directory to use for storing dispatcher state, and for recovering
 during restarts. The empty string indicates not to use any work directory.
 
string work_dir = 3;

public ServiceConfig.DispatcherConfig.Builder setWorkDirBytes (wartość com.google.protobuf.ByteString)

 A work directory to use for storing dispatcher state, and for recovering
 during restarts. The empty string indicates not to use any work directory.
 
string work_dir = 3;